JACC: Cardiovascular Imaging
Volume 5, Issue 2 , Pages 193-202, February 2012

Is Discordance of Coronary Flow Reserve and Fractional Flow Reserve Due to Methodology or Clinically Relevant Coronary Pathophysiology?

  • Nils P. Johnson, MD, MS
  • ,
  • Richard L. Kirkeeide, PhD
  • ,
  • K. Lance Gould, MD

      Affiliations

    • Corresponding Author InformationReprint requests and correspondence: Dr. K. Lance Gould, Weatherhead PET Center for Preventing and Reversing Atherosclerosis, University of Texas Medical School at Houston, 6431 Fannin Street, Room 4.256 MSB, Houston, Texas 77030

Weatherhead PET Center for Preventing and Reversing Atherosclerosis, Division of Cardiology, Department of Medicine, University of Texas Medical School and Memorial Hermann Hospital, Houston, Texas

Received 1 August 2011; received in revised form 12 September 2011; accepted 13 September 2011.

Objectives

The purpose of this study was to determine whether observed discordance between coronary flow reserve (CFR) and fractional flow reserve (FFR) is due to methodology or reflects basic coronary pathophysiology.

Background

Despite the clinical importance of coronary physiological assessment, relationships between its 2 most common tools, CFR and FFR, remain poorly defined.

Methods

The worst CFR and stress relative uptake were recorded from 1,500 sequential cardiac positron emission tomography cases from our center. From the literature, we assembled all combined, invasive CFR-FFR measurements, including a subset before and after angioplasty. Both datasets were compared with a fluid dynamic model of the coronary circulation predicting relationships between CFR and FFR for variable diffuse and focal narrowing.

Results

A modest but significant linear relationship exists between CFR and FFR both invasively (r = 0.34, p < 0.001) and using positron emission tomography (r = 0.36, p < 0.001). Most clinical patients undergoing CFR or FFR measurements have diffusely reduced CFR consistent with diffuse atherosclerosis or small-vessel disease. The theoretical model predicts linear relationships between CFR and FFR for progressive stenosis with slopes dependent on diffuse narrowing, matching observed data. Reported changes in CFR and FFR with angioplasty agree with model predictions of removing focal stenosis but leaving diffuse disease. Although CFR-FFR concordance is common, discordance is due to dominant or absent diffuse versus focal disease, reflecting basic pathophysiology.

Conclusions

CFR is linearly related to FFR for progressive stenosis superimposed on diffuse narrowing. The relative contributions of focal and diffuse disease define the slope and values along the linear CFR and FFR relationship. Discordant CFR and FFR values reflect divergent extremes of focal and diffuse disease, not failure of either tool. With such discordance observed by invasive and noninvasive techniques and also fitting fluid dynamic predictions, it reflects clinically relevant basic coronary pathophysiology, not methodology.

Key Words:  absolute flow quantification , coronary flow reserve , fractional flow reserve , physiology , positron emission tomography

Abbreviations and Acronyms:  CFR, coronary flow reserve, FFR, fractional flow reserve, PCI, percutaneous coronary intervention, PET, positron emission tomography

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 The authors received internal funding from the Weatherhead PET Center for Preventing and Reversing Atherosclerosis. All authors have reported that they have no relationships relevant to the contents of this paper to disclose.

PII: S1936-878X(11)00881-3

doi:10.1016/j.jcmg.2011.09.020

JACC: Cardiovascular Imaging
Volume 5, Issue 2 , Pages 193-202, February 2012